Operating manual
Laser distance meter
Model: ROBOT 60
Manufacturer: ADAINSTRUMENTS Address: WWW.ADAINSTRUMENTS.COM
MEASUREMENT FOUNDATION
2
ROBOT 60
Table of contents
1. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2. Prohibited use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Start up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. Menu functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5. Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6. Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7. Message codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8. Techical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
9. Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
10. Care and cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
11. Specic reasons for erroneous measuring results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
13. Laser classication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
14. Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
15. Exceptions from responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Appendix 1 — “Certicate of acceptance and sale”
Appendix 2 — “Warranty card”
MEASUREMENT FOUNDATION
3
ROBOT 60
Congratulations on the purchase of laser distance meter ADA ROBOT 60!
Permitted use
· Measuring distances
· Computing functions, e.g. areas, volumes, subtractions, Pythagorean calculation
· Storing measurements
The safety regulations and instructions along with the operating manual should be read carefully before initial operation.The
person responsible for the instrument must ensure that equipment is used in accordance with the instructions. This person is also
accountable for the deployment of personnel and for their training and for the safety of the equipment when in use.
Safety instruction
Please follow up instructions given in operators’ manual.
Do not stare into beam. Laser beam can lead to eye injury (even from greater distances).
Do not aim laser beam at persons or animals.
The laser plane should be set up above eye level of persons.
Use the instrument for measuring jobs only.
Do not open instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer.
Do not remove warning labels or safety instructions.
Keep instrument away from children.
Do not use instrument in explosive environment.
MEASUREMENT FOUNDATION
4
ROBOT 60
Prohibited use
— Using the instrument without instruction
— Using outside the stated limits
— Using the instrument in explosive environment (gas station, gas equipment, chemical industry and so on)
— Deactivation of safety systems and removal of explanatory and hazard labels
— Opening of the equipment by using tools (screwdrivers, etc.), as far as not specically permitted for certain cases
— Carrying out modication or conversion of the product
— Don’t shoot at others with the laser intentionally
— Don’t stare at the laser directly.
— Aiming directly into the sun
— Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
— Using the instrument on the plane, near manufacturers, technological objects
Laser classication
The instrument is a laser class 2 laser product with power < 1 mW and wavelength 635 nm.
START UP
Keypad
1 ON / Single measure / Continuous measure
2 Area / Volume / Pythagorean measure
3 Plus / Minus / Units
4 Reference / Illumination
5 Clear / OFF
6 Data storage key
2
4
1
3
5
6
MEASUREMENT FOUNDATION
5
ROBOT 60
Display
1 Laser ON
2 Reference (front/rear)
3 Area / volume/ Pythagorean
4 Hardware error
5 Battery display
6 Data storage
7 Data storage quanity
8 Fixed timing measure
9 Wall space measure
10 Units with exponents ( 2/3 )
11 Auxiliary Display 1
12 Auxiliary Display 2
13 Main display
Inserting / Replacing Batteries
Remove the battery cover, insert the battery correctly. Pay attention to cor-
rect polarity.
Close the battery compartment.
Replace the battery when symbol constantly blinks in the display.
Batteries should be removed in case of danger of corrosion, if the device
will not be used for a long time.
MENU FUNCTIONS
Swtich on and off
Press the button (1) to switch on the instrument and laser.
Press and hold key for about 2 seconds to start continuous measuring.
The device also switches off automatically after 3 minutes of inactivity i.e.
no key is pressed within that interval.
To switch off the instrument press and hold button (5) 2 sec.
Reference Setting
Default reference setting is from the rear of the device.
Press the button (4) to set the reference the front or the rear.
When the end-piece is folded out fully, the reference rear is set.
You will see the reference symbol on the display.
1
2
3
4
11
12
13
5 6 7 8 9
10
MEASUREMENT FOUNDATION
6
ROBOT 60
Selecting Units
Press and hold the button (3) for 2 sec. until the desired unit is displayed.
Illumination
Press and hold the button (4) for 2 seconds to switch the illumination on or off.
Clear-Key
Cancel the last action. Press button (5).
MEASUREMENTS
Single distance measurement
Press button (1) to activate the laser. When in continuous laser mode, press this button to trigger the distance measurement directly.
Press again to trigger the distance measurement. The result is displayed immediately.
Continuous Measurement
Press and hold the button (1) for about 2 seconds to start continuous measuring.
Minimum/ Maximum measurement
This function allows the user to measure the minimum or maximum distance from a xed measuring point. It is commonly used to measure room
diagonals (maximum values) or horizontal distances (minimum values).
Press and hold down the button (1). Then slowly sweep the laser back and forth and up and down over the desired target point-(e.g. into the corner of
a room).
Press to stop continuous measurement. The values for maximum and minimum distances are shown on the display as well as the last measured value
in the summary line.
MEASUREMENT FOUNDATION
7
ROBOT 60
FUNCTIONS
Addition / Subtraction
Distance measuring.
Press button (3): next measurement is added to the previous one. Press button (3): next measurement is substracted from the previous one.
The result is displayed in the second line. Previous value is displayed in the previous line.
Area
Press the button (2) once.The symbol is displayed.
Press button to take the rst measurement (for example, length). Measured value is displayed in the second line.
Press button to take the second measurement (for example, width). Measured value is displayed in the second line. First measurement is displayed in
the rst line. The result of measured area is displayed in the main display area.
Addition / Subtraction of areas
Area measuring – see Area.
Press button (3) to enter into the Addition / Subtraction mode. Area value is displayed in the second line.
Press button (1) to take the rst measurement (for example, length).Press button (1) to take the second measurement (for example, width).
After the completion of area, press button (1), the result of substraction of areas is displayed in the main display area.
If the measurements are not nished, press button (3) to continue calculations.
Volume
For volume measurements, press button (2) twice until the indicator for volume measurement appears on the display.
Press button (1) to take the rst measurement (for example, length). Measured value is displayed in the second line.
Press button (1) to take the second measurement (for example, width). Measured value is displayed in the second line. First measurement is displayed
in the rst line.
Press button (1) to take the third measurement (for example, height). Measured value is displayed in the intermediate rst line.
The volume value will be displayed in the main display area and the previous area value is displayed in the rst line.
MEASUREMENT FOUNDATION
8
ROBOT 60
Indirect measurement
Pythagorean measurement is used in the condition that the objective needing to be measured is covered or has no effective reecting
surface and can’t be measured directly.
Make sure you adhere to the prescribed sequence of measurement:
All target points must be in a horizontal or vertical plane.
The best results are achieved when the instrument is rotated about a xed point (e.g. with the positioning bracket fully folded out and the
instrument placed on a wall) or the instrument is mounted on a tripod.
The minimum / maximum function can be used. The minimum value must be used for measurements at right angles to the target; the
maximum distance for all other measurements.
Indirect measurement – determing a distance using 2 auxilary measurements.
E.g. When height and distance can’t be measured directly.
Press button (2) 3 times. The symbol is displayed. The distance to be measured is blinking in the symbol triangle.
Press button (2) to take distance measuring . The result is displayed in the rst line.
Press button (2) to take distance measuring.
After pressing button (2) the result is displayed in the rst line. The result of the function is displayed in the second line.
Indirect measurement – determing a distance using 3 measurements.
Press button (2) 4 times. The symbol is displayed. The distance to be measured is blinking in the symbol triangle.
Press button (1) to take distance measuring (side of the triangle) . The result of the function is displayed in the second line.
Press button (1) to take distance measuring (height of the triangle) . The result of the measurement is displayed in the rst line.
Press button (1) to take distance measuring (side of the triangle) . The result of the function is displayed in the second line.
The result of the measurement is displayed in the second line.
MEASUREMENT FOUNDATION
9
ROBOT 60
Storage of constant / historical storage
Storage of constant
You can store and recall a frequently used val-
ue (e.g. height of a room). Measure the desired
distance, press and hold the button (6) until
the device beeps to conrm storage.
Recalling the constant
Press the button (6) once to recall the constant
and then press the button (1) to enter it into
your calculation.
History storage
Press the button (6) twice and the previous 20
results (measurements or calculated results)
are shown in reverse order. Use button (3) to
navigate through the records. Press the button
(1) to use the result from the summary line for
further calculations.
INFO CAUSE REMEDY
204 Calculation overow Repeat procedure
252 Temperature too high Cool down instrument
253 Temperature too low Warm up instrument
255 Receiver signal too weak Use target plate
256 Received signal too
strong
Use target plate (grey
side)
257 Wrong measurement Use target plate (brown
side)
258 Wrong initialization Switch on – off the
instrument
ERROR CAUSE REMEDY
Error Hardware error Switch on/off the device
several times and check if
the symbol still appears. If
so please call your dealer
for assistance.
MESSAGE CODES
All message codes are displayed with either “Info” or symbol telephone receiver (Error).
Following mistakes can be corrected.
MEASUREMENT FOUNDATION
10
ROBOT 60
TECHNICAL DATA
Range, without target, m 0.05 to 60
Accuracy, mm ±1.5*
Smallest unit displayed 1 mm
Laser class 2
Laser type 635 nm, <1 mW
IP rating IP 54
Automatic switch off 3 minutes of inactivity
Display illumination yes
Battery life, 2 x AAA > 5000 measurements
Dimensions, mm 116×54×35
Weight 155g
Temperature range:
Storage
Operating
-25º to +70º
0º to +40º
* In favourable conditions (good target surface properties, room temperature).
Maximum deviation occurs under unfavorable conditions such as bright sunlight or when measuring to poorly reecting or very rough
surfaces.
MEASUREMENT FOUNDATION
11
ROBOT 60
Measuring conditions
Measuring range: the range is limited to 60 m. At night, at dusk and when the target is shadowed the measuring range without target plate is increased.
Use a target plate to increase the measurement range during daylight or if the target has a bad reection.
Measuring Surfaces
Measuring errors can occur when measuring toward colorless liquids (e.g. water) or dust free glass, styrofoam or similar semi-permeable surfaces.
Aiming at high gloss surfaces deects the laser beam and measurement errors can occur. Against non-reective and dark surfaces the measuring time
can be increased.
Precautions
Please, handle the instrument with care.
Avoid viabrations and hits.
During transportation put the instrument into the soft bag.
Note: the instrument should be dry!
Care and cleaning
Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth. Do not use aggressive cleaning agents or solutions.
Specic reasons for erroneous measuring results
— Measurements through glass or plastic windows;
— Dirty laser emitting window;
— After instrument has been dropped or hit. Please check the accuracy.
— Large uctuation of temperature: if instrument will be used in cold areas after it has been stored in warm areas (or the other way round) please wait some
minutes before carrying out measurements.
Electromagnetic acceptability (EMC)
It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems);
will be disturbed by other instruments (e.g. intensive electromagnetic radiation nearby industrial facilities or radio transmitters).

Просмотр
Доступно к просмотру 34 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
-
Operating manual Laser distance meter Model: ROBOT 60 Manufacturer: ADAINSTRUMENTS Address: WWW.ADAINSTRUMENTS.COM
-
ROBOT 60 Table of contents 1. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 . Prohibited use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3. Start up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4. Menu functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5. Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 6. Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 7. Message codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 8. Techical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 9. Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 10. Care and cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 11. Specific reasons for erroneous measuring results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 13. Laser classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 14. Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 15. Exceptions from responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Appendix 1 - “Certificate of acceptance and sale” Appendix 2 - “Warranty card” MEASUREMENT FOUNDATION -
ROBOT 60 Congratulations on the purchase of laser distance meter ADA ROBOT 60! Permitted use · Measuring distances · Computing functions, e.g. areas, volumes, subtractions, Pythagorean calculation · Storing measurements The safety regulations and instructions along with the operating manual should be read carefully before initial operation.The person responsible for the instrument must ensure that equipment is used in accordance with the instructions. This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use. Safety instruction Please follow up instructions given in operators’ manual. Do not stare into beam. Laser beam can lead to eye injury (even from greater distances). Do not aim laser beam at persons or animals. The laser plane should be set up above eye level of persons. Use the instrument for measuring jobs only. Do not open instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer. Do not remove warning labels or safety instructions. Keep instrument away from children. Do not use instrument in explosive environment. 3 MEASUREMENT FOUNDATION
- 1
- 2
- 3
- 4
- 34
Характеристики
|
Производитель |
|
|
Поверка |
Нет |
|
Внесен в госреестр |
Да |
|
Кол-во точек начала отсчета |
3 |
|
Встроенный прицел |
Нет |
|
Резьба под штатив, дюйм |
нет |
|
Типоразмер |
AAA |
|
Упаковка |
коробка |
Лазерный дальномер ADA Robot 60 А00240 и другие оригинальные товары в категории лазерные дальномеры (рулетки) доступны на сайте интернет-магазина Бигам в Москве по специальной цене 4490 рублей. Перед покупкой данной модели бренда Ada рекомендуем посмотреть особенности, технические параметры, документацию и сертификаты на продукцию. Также предлагаем сравнить товар лазерный дальномер ADA Robot 60 А00240 с ассортиментом модификаций и аналогов из категории лазерные дальномеры (рулетки) Ada.
-
-
Инструкция
Инструкция.pdf 1.89 МБ
На странице представлена инструкция по эксплуатации и другие материалы производителя о товаре лазерный дальномер ADA Robot 60 А00240, необходимые пользователю. Из руководства пользователя Ada можно узнать устройство изделия, срок службы и комплект поставки. Лазерный дальномер ADA Robot 60 А00240 и все товары серии требуют соблюдения правил использования, обслуживания, ухода и хранения.
-
Похожие товары
Содержание
- Функционал
- Плюсы и минусы
- Отзывы
Дальномер ADA Robot 60 – это третья лазерная рулетка в линейке Robot.

Прибор дистанционно измеряет расстояния от 0,05 до 60 метров с профессиональной точностью 1,5 мм.
Дальномер практически ничем не отличается от предыдущей модели, за исключением наличия памяти на 20 последних измерений и отдельно вынесенной для этой функции клавиши.
Лазерная рулетка ADA Robot 60 оснащена практически всем набором функций для профессионального обмера строительных объектов. Кроме того, благодаря своей доступной стоимости прибор дополнит арсенал домашнего мастера, выполняющего ремонт самостоятельно.
Разрабатывая дизайн лазерных дальномеров серии Robot инженеры, видимо, решили себя не утруждать, а просто делали инструмент. Корпус крепкий, обрезиненный со всех сторон.

Резиновые рельефные накладки увеличивают сцепление с рукой и снижают риск механических повреждений.
Благодаря большим мембранным клавишам выполнять замеры можно даже в перчатках. При нажатии на клавишу издается щелчок, сигнализирующий о выполненном измерении. Это удобно, так как будет слышно сделан замер или кнопка не дожата.
Функционал
Лазерный дальномер ADA Robot 60 быстро считает, время замера 0,5-2 секунды в зависимости от расстояния до измеряемого объекта. После нажатия клавиши измерения издается характерный щелчок, говорящий о проведении замера. После издается звуковой сигнал, оповещающий о том, что измерение выполнено.
Непрерывные измерения позволяют просканировать поверхность и определить максимальное (диагональ) и минимальное расстояние (перпендикуляр).
Вычисление площади всего по двум замерам и определение объема по трем существенно экономят время и облегчают задачу. Не нужно носить с собой калькулятор или производить расчеты на телефоне, нужно всего лишь сделать замеры.
В функционале прибора предусмотрены косвенные вычисления по теореме Пифагора для подсчета неизвестной высоты или диагонали.
Функция сложения и вычитания очень удобны, например, для расчета сложных по форме помещений.
Трехстрочный дисплей оснащен подсветкой для работ в помещениях с недостаточным освещением.
Чтобы не носить с собой ручку и бумагу и постоянно записывать результаты, лазерная рулетка имеет память на 20 последних измерений. Клавиша памяти вынесена отдельно, в отличие от ADA Robot 40.
Производить отсчет можно от трех точек, тыл, фронт, пятка. Пятка (скоба) имеет два положения. Положение скобы под 90° служит для определения расстояния от края какой-либо поверхности, а положение под углом 180° к корпусу предусмотрено для измерения из углов и щелей.

Лазерный дальномер ADA Robot 60, как и большинство лазерных рулеток, предусмотрен для измерений внутри помещений, так как не имеет оптического визира или цифрового видоискателя.
В принципе работы на улице производить можно, но только в потемках, когда лазерная точка будет видна.
Поставляется АДА Робот 60 в стандартной для дальномеров комплектации: сумочка-чехол, ремешок на руку, батарейки, инструкция.

Плюсы и минусы
« + » быстрые замеры, измерение площади и объема, определение минимального и максимального расстояния, память на 20 ячеек, сложение и вычитание, подсветка и звук, три точки отсчета, двухпозиционная пятка, автоматическое переключение на пятку.
« — » дизайн на любителя.
Поставляется 60-й Робот с батарейками, инструкцией и чехлом.
Рекомендуемые обзоры и статьи
Вступайте в наш Telegram канал и группу в Контакте, и вы первыми узнаете о свежих новинках лазерных уровней! Мы надеемся, что наши обзоры помогут вам определится с выбором и сэкономить.